{"id":2721,"date":"1999-03-01T00:59:00","date_gmt":"1999-02-28T22:59:00","guid":{"rendered":"https:\/\/p688098.mittwaldserver.info\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/"},"modified":"2025-03-30T01:04:32","modified_gmt":"2025-03-29T23:04:32","slug":"monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project","status":"publish","type":"project","link":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/","title":{"rendered":"Monitoring studies and analyses of passive houses in the framework of the CEPHEUS-Project"},"content":{"rendered":"\n<p>Ziel dieses Projektes ist die breite Einf\u00fchrung des Passivhausstandards unter Einbeziehung m\u00f6glichst vieler Bautr\u00e4ger. Der gesamte Realisierungsprozess wird fachlich von Passivhaus-Experten betreut und dokumentiert. Neben Foto-Serien zur Dokumentation der Baufortschritte werden auch Qualit\u00e4tstests wie Thermografieaufnahmen und Blower-Door-Tests durchgef\u00fchrt. Um die Funktion und den Erfolg der Passivh\u00e4user nachweisen zu k\u00f6nnen, werden die Geb\u00e4ude mit unterschiedlicher Differenziertheit und zeitlicher Aufl\u00f6sung ein Jahr lang vermessen.   <\/p>\n\n<p>Die AEE INTEC ist f\u00fcr das Messkonzept der \u00f6sterreichischen Projekte, die Gesamtkoordination der Realisierung sowie f\u00fcr die Betreuung und laufende \u00dcberwachung der Messungen w\u00e4hrend des Messjahres zust\u00e4ndig. Die Messdaten werden laufend mittels Modem ausgelesen und in einer SQL-Datenbank auf Plausibilit\u00e4t \u00fcberpr\u00fcft. Letztendlich werden dem Energieinstitut Vorarlberg, als Projektleiter der \u00f6sterreichischen Projekte, die Messdaten zur Interpretation entsprechend zusammengefasst \u00fcbergeben. Insgesamt wurden im Rahmen des CEPHEUS-Projektes in f\u00fcnf europ\u00e4ischen L\u00e4ndern \u00fcber 200 Wohneinheiten errichtet. In \u00d6sterreich wurden 83 Wohneinheiten an 9 Standorten realisiert.    <\/p>\n","protected":false},"author":4,"featured_media":2720,"parent":0,"menu_order":0,"template":"","class_list":["post-2721","project","type-project","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Monitoring studies and analyses of passive houses in the framework of the CEPHEUS-Project - AEE INTEC<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/\",\"url\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/\",\"name\":\"Monitoring studies and analyses of passive houses in the framework of the CEPHEUS-Project - AEE INTEC\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aee-intec.at\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/bilder55.jpg\",\"datePublished\":\"1999-02-28T22:59:00+00:00\",\"dateModified\":\"2025-03-29T23:04:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.aee-intec.at\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/bilder55.jpg\",\"contentUrl\":\"https:\\\/\\\/www.aee-intec.at\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/bilder55.jpg\",\"width\":350,\"height\":191},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/home-page\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Project\",\"item\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/project\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Monitoring studies and analyses of passive houses in the framework of the CEPHEUS-Project\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/\",\"name\":\"AEE - Institut f\u00fcr Nachhaltige Technologien\",\"description\":\"Willkommen bei AEE - Institut f\u00fcr Nachhaltige Technologien - AEE INTEC\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/#organization\",\"name\":\"AEE - Institut f\u00fcr Nachhaltige Technologien\",\"url\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aee-intec.at\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/logo-1.gif\",\"contentUrl\":\"https:\\\/\\\/www.aee-intec.at\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/logo-1.gif\",\"width\":74,\"height\":96,\"caption\":\"AEE - Institut f\u00fcr Nachhaltige Technologien\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aee-intec.at\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/at.linkedin.com\\\/company\\\/aee-intec\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC7y2Y-8u6IXEJXbVlEy_vew\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Monitoring studies and analyses of passive houses in the framework of the CEPHEUS-Project - AEE INTEC","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/","url":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/","name":"Monitoring studies and analyses of passive houses in the framework of the CEPHEUS-Project - AEE INTEC","isPartOf":{"@id":"https:\/\/www.aee-intec.at\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/#primaryimage"},"image":{"@id":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aee-intec.at\/wp-content\/uploads\/2025\/03\/bilder55.jpg","datePublished":"1999-02-28T22:59:00+00:00","dateModified":"2025-03-29T23:04:32+00:00","breadcrumb":{"@id":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/#primaryimage","url":"https:\/\/www.aee-intec.at\/wp-content\/uploads\/2025\/03\/bilder55.jpg","contentUrl":"https:\/\/www.aee-intec.at\/wp-content\/uploads\/2025\/03\/bilder55.jpg","width":350,"height":191},{"@type":"BreadcrumbList","@id":"https:\/\/www.aee-intec.at\/en\/project\/monitoring-studies-and-analyses-of-passive-houses-in-the-framework-of-the-cepheus-project\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aee-intec.at\/en\/home-page\/"},{"@type":"ListItem","position":2,"name":"Project","item":"https:\/\/www.aee-intec.at\/en\/project\/"},{"@type":"ListItem","position":3,"name":"Monitoring studies and analyses of passive houses in the framework of the CEPHEUS-Project"}]},{"@type":"WebSite","@id":"https:\/\/www.aee-intec.at\/en\/#website","url":"https:\/\/www.aee-intec.at\/en\/","name":"AEE - Institut f\u00fcr Nachhaltige Technologien","description":"Willkommen bei AEE - Institut f\u00fcr Nachhaltige Technologien - AEE INTEC","publisher":{"@id":"https:\/\/www.aee-intec.at\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aee-intec.at\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.aee-intec.at\/en\/#organization","name":"AEE - Institut f\u00fcr Nachhaltige Technologien","url":"https:\/\/www.aee-intec.at\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aee-intec.at\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.aee-intec.at\/wp-content\/uploads\/2025\/02\/logo-1.gif","contentUrl":"https:\/\/www.aee-intec.at\/wp-content\/uploads\/2025\/02\/logo-1.gif","width":74,"height":96,"caption":"AEE - Institut f\u00fcr Nachhaltige Technologien"},"image":{"@id":"https:\/\/www.aee-intec.at\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/at.linkedin.com\/company\/aee-intec","https:\/\/www.youtube.com\/channel\/UC7y2Y-8u6IXEJXbVlEy_vew"]}]}},"_links":{"self":[{"href":"https:\/\/www.aee-intec.at\/en\/wp-json\/wp\/v2\/project\/2721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aee-intec.at\/en\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/www.aee-intec.at\/en\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/www.aee-intec.at\/en\/wp-json\/wp\/v2\/users\/4"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aee-intec.at\/en\/wp-json\/wp\/v2\/media\/2720"}],"wp:attachment":[{"href":"https:\/\/www.aee-intec.at\/en\/wp-json\/wp\/v2\/media?parent=2721"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}